Maquet Siemens 900 C

The Maquet Siemens 900 C features Volume controlled, volume control with sight, pressure controlled, pressure support.

Category: Tags: , ,

Product Description

The Maquet Siemens 900 C features:

DIMENSIONS: 50cm x 23cm x 32cm
WEIGHT: 19kg (42lbs) – without accessories.

Control Ranges

WORKING PRESSURE: Up to 120cm H2O.
MODES: Volume controlled, volume control with sight, pressure controlled, pressure support, synchronized intermittent mandatory ventilation (SIMV), SIMV+ pressure support, continous positive airway pressure, manual ventilation.
Present inspiratory minute volume: .5 – 40 1/min, with sufficient working pressure.
FLOW PATTERN: constant, accelerating or decelerating.
RESPIRATORY RATE: 5-120 breaths/min.
INSPRIATORY TIME: 20-80% of respiratory cycle.
PAUSE TIME: 0-30% of respiratory cycle.
PEEP: 0-50cm H2O.
UPPER LIMIT: 15-120cm H2O
TRIG SENSITIVITY: -20-0cm H2O (below PEEP)
SIMV RATE: high rate (4-40 SIMV breaths/min), low rate (.4-4 SIMV breaths/min).
SIGHT: double tidal volume possible every 100 breaths.
COMPRESSED VOLUME: 0.075 1(internal).
Monitoring

ANALOG PRESENTATION:
AIRWAY PRESSURE: -20 – 120cm H2O
EXPIRED MINUTE VOL: adults 0-40 1/min, infants 0-4 1/min.
DIGITAL PRESENTATIONS:
RESPIRATORY RATE: 5-120 breaths/min.
O2 CONCENTATION: in % by volume, 20-100%.
INSPIRED TIDAL VOLUME: 0-1999 ml.
EXPIRED TIDAL VOLUME: 0-1999ml.
EXPIRED MINUTE VOLUME: adults 0-40 1/min, infants 0-4 1/min.
PEAK PRESSURE: 0-120cm H2O
PAUSE PRESSURE: 0-120cm H2O
MEAN AIRWAY PRESSURE: 0-120CM H2O
Gas & Power Supply

Must fulfill specifications for medical gases.
GAS CONSUMPTION: approximately equal to preset inspiratory minute volume or equal to flow meter setting.
GAS SUPPLY VIA HIGH PRESSURE INLET: from central gas supply, compressor or gas cylinder.
ELECTRONIC GAS SUPPLY UNIT, INLET PRESSURE: 2.5-5 bar (250-500 kPa; 35-70 psi).
OTHER GAS SUPPLY INLET PRESSURE: 2.5-7 bar (250-700 kPa; 35-100 psi).
GAS SUPPLY VIA LOW PRESSURE INLET: vial flowmeters.
POWER SUPPLY: (100), 110, 120, 220, 240, 50 OR 60 hZ.
POWER CONSUMPTION: Approximately 40 W.
Alarms & Indicatators

PUSH BUTTON: audible signals, muted for 2 min maximum.
ALARMS: gas supply alarm, apnea alarm, expired minute volume, O2 concentration, upper pressure limit, power failure.
INDICATORS: set minute volume alarm, set O2 alarm, set O2 alarm, pressure support, CPAP, MAN SIMV high/low rate, expired minute volume infants, patient trig.
Special Funtions

Inspiratory pause hold, expiratory pause hold gas exchange.